产品中心
PRODUCT CENTER
                        联系我们
                        Contact us
                    
                    
                            联系电话:
                            010-82781816
                        
                        
                            公司地址:
                            北京市海淀区农大南路1号院硅谷亮城2号楼B519
                        
                         
                            
                                扫一扫
                                获取更多详情
                            
                        
                    首页 >> 
                    产品中心
                
                 
                             
                                    FGT
                                FGT 高灵敏度伽马工具是下一代“屏蔽”伽马,非常适合方位地质导向应用。与竞争工具相比,FGT 具有更高的额定温度 (182°C)、更高 的振动 (25 GRMS)、更高的灵敏度和更大的前后计数比。FGT 是CBG行业标准产品 DGA-C 的完全电气和机械重新设计。
FGT 采用一个由钨材料加工而成的“窗口”,该窗口围绕着晶体和光电管。从地层发射的伽马射线可以不衰减地通过这个窗口进入,进行检测和计数。与其他聚焦伽马射线探测器相比,FGT的更大窗口提高了检测灵敏度,并改善了低伽马射线活跃区的可见性。当与工具面或其他物理参考对齐时,FGT 指示伽马射线能量的来源方向。
FGT 包含 CBG 正在申请专利的新电子设计。电子电路板封装在预成型的高温硅胶垫中,可免受极端冲击和振动。一种用于提供电子元件温度补偿的新型创新技术可确保在整个工作温度范围内提供更稳定的输出信号。另外增加的突发滤波器,可以减少因过度冲击和振动以及外部瞬态噪声而导致的伪杂散计数。
                            
                         产品详情
                            产品详情
                        FGT Specifications
P/N 202-200-000
| Detector | Scintillator Crystal | Sodium Iodide, Na(TI) | 
|---|---|---|
| Photomultiplier | R3991A (Hamamatsu) | |
| Mechanical | Diameter (OD) | 1.36” | 
| Length (make-up) | 13.6” | |
| Weight | TBD | |
| End Connectors | Micro-D Subminiature, 15-Pin | |
| Material | Aluminum Alloy (chassis), Tungsten (shield) | |
| Performance | Sensitivity | TBD | 
| Front/Back Count Ratio (using source at 6”) | TBD | |
| Accuracy | +/- 5% to 150°C +/- 10% to 182°C | |
| Environmental | Operating Temperature | -18°C to 182°C | 
| Survival Temperature | -40°C to 200°C | |
| Heat/Cool Rate, Max. | 2.8°C (5°F) per minute | |
| Vibration (3 axis) 50-1000Hz, Random | 35G (25G RMS) | |
| Shock (3 axis) | 1000G, 0.5ms, half-sine | |
| Burst Filter | Reduces spurious counts due to extreme shock/vibration and external system electronic noise. | |
| Power Requirements | DC Input Voltage | 10v – 50v, 60v Max. | 
| Tool Current | 8-11 mA | |
| Output Signal | Negative Pulse | +5V to GND, 5 uSec width | 
* Counts are collected with gamma tool mounted within a standard BeCu pressure barrel, (OD 1.875″, ID 1.500″). API Calibration performed with AEA Technology, QSA Inc., KUTh Field Verifier #188074, S/N 255 Radionuclides: K-40(11.7%), U-238(90 ppm), Th-232(40 ppm).